Rokonet ORBiT-14 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnostní systémy pro řízení přístupu Rokonet ORBiT-14. Rokonet ORBiT-14 User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 70
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation and Programming Manual
1
Section 1: About Your ORBIT-Pro
I
I
n
n
t
t
r
r
o
o
d
d
u
u
c
c
t
t
i
i
o
o
n
n
t
t
o
o
t
t
h
h
i
i
s
s
M
M
a
a
n
n
u
u
a
a
l
l
This ORBIT-Pro Installation and Programming Manual is designed to take you through the required steps so you
can successfully install the ORBIT-Pro and have it perform as desired. To this end, the manual is divided into two
distinct installation and programming sections. The first of these, beginning on page 11, discusses how to install
and wire the panel to its peripherals. The next section, beginning on page 26, covers the programming of the panel
using an attached keypad.
While not required for these purposes, the following documents are also available to assist you in the installation of
your ORBIT-Pro.
DOCUMENT PART NO. DESCRIPTION
The ORBIT-Pro Installer
Programming Worksheets
5IN296PW
a series of tables for recording the programmed data unique
to an account
The ORBIT-Pro Upload/Download
Programming Manual
5IN296UD
explains how programming can be done through the use of
an IBM
®
-compatible Personal Computer
The ORBIT-Pro User’s Manual 5IN296UM provides information intended for ORBIT-Pro’s end users
A
A
b
b
o
o
u
u
t
t
t
t
h
h
e
e
O
O
R
R
B
B
I
I
T
T
-
-
P
P
r
r
o
o
The ORBIT-Pro is a full-featured security system and provides sophisticated solutions for protecting, alerting, and
reporting premises’ alarm signals, intended to address the needs of virtually every home, office, and commercial
facility. It is designed around microprocessor and EEPROM (Electrically Erasable Programmable Read-Only
Memory) technology–which will store, without the need for power, the system’s operating program as well as its
programmable parameters. The ORBIT-Pro supports most standard detectors and sensors, along with a variety of
accessories and output devices.
It can provide monitoring and supervision for up to 96 zones. Through its 4-wire BUS, it can support a variety of
optional modules including multiple Keypads, Zone Expanders, a Wireless Interface, supplemental Power
Supply(ies), a Digital Voice Module, capabilities for Access Control, an X-10 Interface, and Utility Outputs. All these
devices communicate with the system by sending commands and data over the BUS, which originates at the Main
Board.
The ORBIT-Pro utilizes commercial electricity as its primary means of power and supports a rechargeable standby
battery. Its components and features are listed below:
Main Board
The Main Board is the center of the system’s operation. It supports 8 hardwired zones, provides continuous
auxiliary power for detectors like PIRs, and other peripherals (e.g. Audio Switches and certain Shock and Glass-
Break Sensors) which require it. The Main Board also maintains a source of resettable power for Smoke Detectors
when latched in the alarm state. It supplies power for the operation of an external sounder and offers the
appropriate type of voltage for an electronic siren(s), a bell(s), or a loudspeaker(s).
Up to 20 Zone Types are supported.
Zone terminations include Closed-Circuit, Open-Circuit, End-of-Line (EOL) Resistor, and Double End-of-Line
(DEOL) Resistor (see Figure 2-4 on page 22).
It is from the Main Board that the 4-wire BUS originates and from which all system expansion takes place (see
Figure 2-6 on page 24).
Zone Expansion
In addition to its eight hardwired zones, the ORBIT-Pro can support up to another 88 such zones (96 total) which
are derived through the connection of either 8-Zone or 16-Zone Expansion Module(s), including the Wireless
Expansion Modules (not for UL Installations) discussed below.
Zobrazit stránku 0
1 2 3 4 5 6 ... 69 70

Shrnutí obsahu

Strany 1 - Zone Expansion

Installation and Programming Manual1Section 1: About Your ORBIT-ProIInnttrroodduuccttiioonn ttoo tthhiiss MMaannuuaallThis ORBIT-Pro Installation a

Strany 2 - Partitions

Installation and Programming Manual10Power Supply Expansion ModuleInput Power: 16.5 Volts AC @ 40 VA (via transformer)Rechargeable Standby Battery: 12

Strany 3

Installation and Programming Manual11Section 2: Installing Your ORBIT-ProIt's easy to wire up the panel, its keypad(s), and any Expansion Module(

Strany 4

Installation and Programming Manual12WWiirriinngg tthhee MMaaiinn BBooaarrdd(see Figures 2-4, 2-6, 2-7 on pages 22, 24 and 25)CONNECTION COMMENTSEx

Strany 5 - Synoptic Map

Installation and Programming Manual13Wiring to External SoundersExternal SoundersBELL/S+ –Jumper J3 § connect suitable wire to the external sounding

Strany 6 - Figure 1-2

Installation and Programming Manual14IIddeennttiiffyyiinngg aanndd WWiirriinngg KKeeyyppaaddss aanndd EExxppaannssiioonn MMoodduulleess(refer to

Strany 7

Installation and Programming Manual15Wiring the Zone Expansion Module(s)TERMINALS COMMENTSDIP Switches §§ each Zone Expansion Module must be given a u

Strany 8

Installation and Programming Manual16Wiring the Power Supply Expansion ModuleCONNECTIONS COMMENTSDIP Switches § each Power Supply (Expansion) Module m

Strany 9

Installation and Programming Manual17Wiring the Utility Output Expansion ModuleCONNECTIONS COMMENTSDIP Switches §§ each Utility Output Module must be

Strany 10 - X-10 Transmitter Module

Installation and Programming Manual18in feet in meters 22 20 18 16 14up to 15 ft up to 5 m415 – 25 ft 5 – 8 m425 – 40 ft 8 – 12 m440 – 60 ft 12 – 20

Strany 11

Installation and Programming Manual19Figure 2-1

Strany 12

Installation and Programming Manual2Wireless ExpansionWhen it's either necessary or desirable to utilize wireless zones, the ORBIT-Pro's Wir

Strany 13

Installation and Programming Manual20Figure 2-2

Strany 14

Installation and Programming Manual21Figure 2-3

Strany 15

Installation and Programming Manual22Zone TerminationsFigure 2-4Closed-circuit and Open-circuit loops: Not for use in UL Installations

Strany 16

Installation and Programming Manual23 Figure 2-5

Strany 17

Installation and Programming Manual24Figure 2-6

Strany 18 - Draw per Branch

Installation and Programming Manual25Wiring DiagramFigure 2-7

Strany 19 - Figure 2-1

Installation and Programming Manual26Section 3: Programming Your ORBIT-ProSSuummmmaarryy ooff IInnssttaalllleerr PPrrooggrraammmmiinngg MMeetthhoo

Strany 20 - Figure 2-2

Installation and Programming Manual27PPrreeppaarriinngg YYoouurr OORRBBIITT--PPrroo ffoorr IInnssttaalllleerr PPrrooggrraammmmiinnggThere are thr

Strany 21 - Figure 2-3

Installation and Programming Manual28C. Initial Programming:8- Observe the Following and Perform these Initial Stepsa) After about 20 seconds, the key

Strany 22 - Zone Terminations

Installation and Programming Manual29h) press the [ENTER] key; the resulting display confirmsthe following information about the keypad:• it has been

Strany 23 - Figure 2-5

Installation and Programming Manual3Expansion BusThrough the ORBIT-Pro’s 4-wire BUS, which can be run up to 1000 feet, a variety of features and enhan

Strany 24 - Figure 2-6

Installation and Programming Manual30DDeessccrriippttiioonn aanndd UUssee ooff tthhee LLCCDD KKeeyyppaadd The LCD Keypad has been designed to as

Strany 25 - Wiring Diagram

Installation and Programming Manual31 11 press this key to: • enter selected information into the system • accept the current selection and move to

Strany 26 - * Not for UL Installations

Installation and Programming Manual32IInnssttaalllleerr PPrrooggrraammmmiinngg BBaassiiccssThe LCD Keypad offers you the facility to navigate throug

Strany 27 - 7- Apply Power to the System

Installation and Programming Manual33PPrrooggrraammmmiinngg CCllaassssiiffiiccaattiioonnssThe SYSTEM category is one of ORBIT-Pro’s eight programming

Strany 28 - ↓↓

Installation and Programming Manual34INSTALLER PROG:1)SYSTEM ↓↓INSTALLER PROG:2)ZONES ××INSTALLER PROG:3)UTIL OUTPUT ××INSTALLER PROG:4)

Strany 29

Installation and Programming Manual35INSTALLER PROGRAMMING TUTORIALThe following exercise is designed to acquaint you with techniques for navigating t

Strany 30 - Figure 3-1: The LCD Keypad

Installation and Programming Manual36EXAMPLE 3: Adding A Zone Expansion Module1- Press the [S] key until you are returned to yourprevious selection in

Strany 31

Installation and Programming Manual37OORRBBIITT--PPrroo IInnssttaalllleerr PPrrooggrraammmmiinngg MMaapp ((PPaaggee 11 ooff 22))HOMEINSTALL

Strany 32

Installation and Programming Manual38OORRBBIITT--PPrroo IInnssttaalllleerr PPrrooggrraammmmiinngg MMaapp ((PPaaggee 22 ooff 22))SUBJECT: SY

Strany 33 - 1)SYSTEM ↓↓

Installation and Programming Manual39 INSTRUCTIONS FOR USING THE PROGRAMMING MATERIAL(on pages 40 through 112)The remainder of this manual contains i

Strany 34

Installation and Programming Manual4Access Control Expansion Module (Not for UL Installations)One of ORBIT-Pro's most unique features is its abil

Strany 35

Installation and Programming Manual401) SystemThe following parameters are used for programming configuration settings applicable tothe entire system

Strany 36

Installation and Programming Manual41SYSTEM: TIME DEFINE (cont’d)Quick Key Item Default Range ExplanationTIME DEFINE (cont’d)1 1 7 Zone Test Times ---

Strany 37 - IMPORTANT:

Installation and Programming Manual42SYSTEM: SYSTEM CONTROLQuick Key Item Default Explanation1↓↓SYSTEM CONTROL --- Controls Specific System Operations

Strany 38

Installation and Programming Manual43SYSTEM: SYSTEM CONTROLQuick Key Item Default ExplanationSYSTEM CONTROL (cont’d)1 2 14 Alarm ZE Cut NOif YES: prod

Strany 39 - (on pages 40 through 112)

Installation and Programming Manual44SYSTEM: SYSTEM CONTROLQuick Key Item Default ExplanationSYSTEM CONTROL (cont’d)1 2 22 Forced KeyswitchArmingNot f

Strany 40 - INSTALL PROG:

Installation and Programming Manual45SYSTEM: SYSTEM CONTROLQuick Key Item Default ExplanationSYSTEM CONTROL (cont’d)1 2 24 Arm Pre-Warning NOif YES: f

Strany 41 - SYSTEM: TIME DEFINE (cont’d)

Installation and Programming Manual46SYSTEM: SYSTEM LABELQuick Key Item Default Explanation1 5 SYSTEM LABEL---Creates and Edits System and Partition L

Strany 42 - SYSTEM: SYSTEM CONTROL

Installation and Programming Manual47SYSTEM: SERVICE INFORMATIONQuick Key Item Default Explanation1 8SERVICEINFORMATION---Supplies Servicing Informati

Strany 43

Installation and Programming Manual482) ZonesThe following parameters are used for programming the characteristics of each of the system’s protective

Strany 44

Installation and Programming Manual49 § IMPORTANT: § in One-By-One, the listing of each zone’s parameters aresequential; thus, once Zone 1’s paramete

Strany 45

Installation and Programming Manual5Self MonitoringThe ORBIT-Pro has a “watchdog” feature, which periodically and automatically performs a comprehensi

Strany 46 - 1)PARTITION 1

Installation and Programming Manual50ZONES: ZONE PARTITIONSZONES: ZONE TYPEQuick Key Item Default Explanation2 2PARTITIONSall zonesareassignedtoPartit

Strany 47 - SYSTEM: SERVICE INFORMATION

Installation and Programming Manual51ZONES: ZONE TYPE (cont’d)Quick Key Item Default ExplanationZONE TYPE (cont’d)0 Instant default forall zonesexcept

Strany 48 - 2)ZONES ↓↓

Installation and Programming Manual52ZONES: ZONE TYPE (cont’d)Quick Key Item Default ExplanationZONE TYPE (cont’d)12 Day --- § usually assigned to an

Strany 49

Installation and Programming Manual53ZONES: ZONE SOUNDQuick Key Item Default ExplanationZoneSoundZONE SOUND--- § programs ONLY the sounds produced whe

Strany 50

Installation and Programming Manual54ZONES: TERMINATIONZONES: LOOP RESPONSEQuick Key Item Default Explanation2 5 ZoneTerminationTERMINATION---

Strany 51 - ZONES: ZONE TYPE (cont’d)

Installation and Programming Manual55ZONES: CROSS ZONESQuick Key Item Default Explanation2 7CROSS ZONESNot for UL Installationsnocrosszoning § for add

Strany 52

Installation and Programming Manual56ZONES: LABELSQuick Key Item Default Explanation2 8LABELSZONE 01ZONE 02ZONE 03ZONE 04etc. § allows for the creatio

Strany 53 - ZONES: ZONE SOUND

Installation and Programming Manual57ZONES: MAINTENANCEQuick Key Item Explanation2 9 MAINTENANCE § provides some useful tools to perform system mainte

Strany 54 - Response

Installation and Programming Manual58ZONES: MAINTENANCE (cont’d)Quick Key Item ExplanationMAINTENANCE(cont’d) § the following material relates to the

Strany 55

Installation and Programming Manual59ZONES: MAINTENANCE (cont’d)Quick Key Item Explanation2 9 7 Zone Self TestNot for ULInstallations § this feature p

Strany 56

Installation and Programming Manual6Figure 1-2

Strany 57

Installation and Programming Manual60ZONES: MAINTENANCE (cont’d)Quick Key Item Explanation2 9 7 Zone Self Test(cont’d)CHOOSING A TESTING SCHEDULE § in

Strany 58 - 2)SYSTEM ↓↓

Installation and Programming Manual61ZONES: MAINTENANCE (cont’d)Quick Key Item Explanation2 9 7 Zone Self Test(cont’d)i) and press [ENTER]ii) at this

Strany 59

Installation and Programming Manual62ZONES: MISCELLANEOUSQuick Key Item Default Explanation2 0 MISCELLANEOUS2 0 1 xx+ENTERForced ArmingNot for ULInst

Strany 60

Installation and Programming Manual633) Utility OutputsBy adding one or more Utility Output Expansion Modules to the system, an extensive list of swit

Strany 61

Installation and Programming Manual64UTILITY OUTPUT: SYSTEM (cont’d)Quick Key Utility Output Follows Default Explanation SYSTEM (cont’d)5Ground Pulse

Strany 62

Installation and Programming Manual65UTILITY OUTPUT: PARTITIONQuick Key Utility Output Follows Default ExplanationPARTITION--- § the Utility Output w

Strany 63 - Trouble Follow

Installation and Programming Manual66UTILITY OUTPUT: PARTITION (cont’d)Quick Key Utility Output Follows Default ExplanationPARTITION (cont’d)10Chime F

Strany 64 - Sensors Test

Installation and Programming Manual67UTILITY OUTPUT: ZONEQuick Key Utility Output Follows Default ExplanationZONE--- § the Utility Output will follow

Strany 65 - Y

Installation and Programming Manual68UTILITY OUTPUT: CODEQuick Key Utility Output Follows Default Explanation4 CODE--- § activates the designated Uti

Strany 66 - 3) UO ↓↓

Installation and Programming Manual69UTILITY OUTPUT (cont’d)Quick Key Pattern of Operation: Default Explanationchoose among the following patterns for

Strany 67 - UTILITY OUTPUT: ZONE

Installation and Programming Manual7IInnvveennttoorryy SSuupppplliieedd wwiitthh tthhee OORRBBIITT--PPrrooThe ORBIT-Pro is sold with one of four k

Strany 68 - UTILITY OUTPUT: CODE

Installation and Programming Manual704) Code MaintenanceThe ORBIT-Pro supports up to 99 unique User Codes (known by a number from “00” through “98”)–e

Strany 69 - UTILITY OUTPUT (cont’d)

Installation and Programming Manual8OORRBBIITT--PPrroo AAcccceessssoorriieessITEM DESCRIPTIONKeypadsRP296KL8 8-LED KeypadRP296KL16 16-LED KeypadRP296

Strany 70 - 4) Code Maintenance

Installation and Programming Manual9TTeecchhnniiccaall DDaattaaControl PanelInput Power: 16.5 Volts AC @ 40 Volt-Amps (VA) (via transformer)Rechargea

Komentáře k této Příručce

Žádné komentáře